Lankhorst Taselaar

6 407 T | +31 (0)320 274611 AC MASTER AC Master 12/1000 AC Master 12/1500 AC Master 12/2500 AC Master 12/3500 14.662.053 14.662.054 14.662.055 14.662.056 28011000 28011500 28012500 28013500 200/220/230/240V - 50/60Hz 200/220/230/240V - 50/60Hz 230/240V - 50/60Hz 230/240V - 50/60Hz (selectable) (selectable) (selectable) (selectable) true sine true sine true sine true sine 12V 12V 12V 12V ≥ 130Ah ≥ 160Ah ≥ 270Ah ≥ 360Ah 1000W 1500W 2500W 3500W 1000W 1500W 2500W 3500W < 1150W (1 min.) / 1750W (1 sec.) 1730W (1min.) / 2650W (1 sec.) < 300W (1 min.) / < 4000W 4500W (1 min.) / 6000W (1 sec.) (1 sec.) plug connection EU (Schuko) or UK plug connection EU (Schuko) or UK hardwired + plug connection hardwired + plug connection EU (Schuko) EU (Schuko) 92% 93% 88% 90% n.a. n.a. yes, up to 15 units yes, up to 15 units n.a. n.a. yes, 3 units yes, 3 units LED indication: battery voltage, load LED indication: battery voltage, load LED indication: battery voltage, LED indication: battery voltage, level, status level, status load level, status load level, status 200 x 372 x 83mm 248 x 421 x 83mm 283 x 436 x 128mm 283 x 436 x 128mm 3,3kg 4,2kg 8kg 10kg potential free alarm contact potential free alarm contact potential free alarm contact potential free alarm contact CE, E-mark, RCM CE, E-mark, RCM CE, E-mark, RCM CE, E-mark, RCM high frequency, input & output fully isolated high frequency, input & output fully high frequency, input & output high frequency, input & output isolated fully isolated fully isolated 100A 150A 250A 350A < 0,1A < 0,1A < 1,1A < 1,4A 125A 175A 300A 400A 35mm² 50mm² 95mm² 120mm² < 5% < 3% < 3% < 3% all power factors allowed all power factors allowed all power factors allowed all power factors allowed n.a. n.a. integrated, automatic (inverter integrated, automatic (inverter to grid: 8~10 ms, grid to to grid: 8~10 ms, grid to inverter: 16~50 ms). Not for inverter: 16~50 ms). Not for parallel & 3-phase operation parallel & 3-phase operation (external transfer system (external transfer system possible). possible). -20°C to 40°C, derating power ≥ 40°C -20°C to 40°C, derating power ≥ 40°C -20°C to 60°C, derating -20°C to 60°C, derating power > 40°C power > 35°C IP21, horizontal wall mounting IP21, horizontal wall mounting IP21, horizontal wall mounting IP21, horizontal wall mounting over-temperature, overload, short circuit, over-temperature, overload, short over-temperature, overload, over-temperature, overload, high/low voltage, reverse polarity (fuse) circuit, high/low voltage, reverse short circuit, high/low voltage, short circuit, high/low voltage, polarity (fuse) reverse polarity (fuse) reverse polarity (fuse) temperature and load controlled fan temperature and load controlled fan temperature and load temperature and load controlled controlled fan fan no no no no CHARGERS

RkJQdWJsaXNoZXIy ODY1MjQ=