6 495 LIGHTS, ON-BOARD ELECTRICS T | +31 (0)320 274611 Art.no Man. no Description 21.352.254 220026 inline terminator Art.no Man. no Description 21.352.252 220013 male terminator Art.no Man. no Description 21.352.251 220012 female terminator NMEA2000 TERMINATOR NMEA2000 L-CONNECTOR Art.no Man. no Description 21.352.268 220023 T-connector 4 ports Art.no Man. no Description 21.352.267 220022 T-connector 2 ports Art.no Man. no Description 21.352.250 220010 T-connector NMEA2000 T-CONNECTOR NMEA2000 DROP/BACKBONE CABLE These drop - and backbone cables are universal and compatible with other manufacturer's NMEA2000 products. The cable has large 18 AWG power conductors to minimize the risk of voltage drop and provide better reliability to the NMEA2000 network. Each drop cable is limited to 6 meters maximum and a total of 78 meters length of all drop cables in the network is possible. The maximum length of the backbone cable is 100 meters. • Voltage rating 300 VAC/VDC • max 4A • IP68 • Impedance 120 Ohm Art.no Man. no Description Length m 21.352.301 220033 Drop cable/backbone cable 0,25 21.352.260 220014 Drop cable/backbone cable 0,5 21.352.261 220015 Drop cable/backbone cable 1,0 21.352.262 220016 Drop cable/backbone cable 2,0 21.352.263 220017 Drop cable/backbone cable 4,0 21.352.264 220018 Drop cable/backbone cable 6,0 21.352.265 220019 Backbone cable 8,0 21.352.266 220024 Backbone cable 10,0 The T-connector is required for adding components and constructing a NMEA2000 network. It is installed on the backbone cable and uses one end of the T-connector for the drop cable. • NMEA2000 network standard, compatible with other manufacturer's NMEA2000 products • IP68 The L-connector is perfect to use in tight spaces to reduce stress between two cables. It can also be connected to a NMEA2000 gauge in the dashboard where there often is lack of space. This will create a compact and neat installation. • NMEA2000 network standard, compatible with other manufacturer's NMEA2000 products • IP68 Art.no Man. no Description 21.352.253 220025 L-connector A NMEA2000 network needs terminating resistors at either end, to terminate or close the NMEA 2000 network a terminator should be installed on one side of a T-connector. One female and one male are required for a proper NMEA2000 installation. The inline terminator can be used at the end of a NMEA2000 backbone to terminate the backbone and still allow for a single device to be used after the terminator without a T-connector and standard terminator. It can for example be used to connect a compatible NMEA2000 device in the top of a sailboat mast. The inline terminator is working like a normal terminator and will terminate the NMEA2000 network. It will function properly as an end terminator even if there's nothing connected to the other end of the inline terminator. • NMEA2000 network standard, compatible with other manufacturer's NMEA2000 products • IP68 • 120 Ohm WEMA INSTRUMENTS
RkJQdWJsaXNoZXIy ODY1MjQ=